LCR45 Atlas Passive Component Impedance Analyser (Model LCR45) PEAK ELECTRONICS

ΚΩΔΙΚΟΣ 55246.MMM.T4. Σε απόθεμα 4 Τεμάχια ΚΑΤΑΣΚΕΥΑΣΤΗΣ Peak Electronics - Atlas
Κατάσταση Καινούργιο
Δασμολογικός Κωδικός 90303320
Χώρα Παραγωγής United Kingdom
99,00 €
χωρίς ΦΠΑ
Quantity
Αποστέλλεται σε 1-2 εργάσιμες ημέρες
A great handheld LCR analyser that can measure the value of your passive component (inductor, capacitor or resistor) and also measure the detailed impedance in a number of modes. The LCR45 offers enhanced measurement resolution (better than 0.1uH!) whilst also giving you continuous fluid measurements. Additionally, the test frequencies of DC, 1kHz, 15kHz and 200kHz can be set to automatic or manual modes. Supplied with removable gold plated hook probes, battery and user guide. Compatible with standard 2mm test connectors. Not designed for in-circuit use.

Key Features

  • Automatic or manual component type selection: Inductor, Capacitor or Resistor.
  • Automatic or manual test frequency selection: DC, 1kHz, 15kHz and 200kHz.
  • Inductance from 0.1uH to 10H.
  • Capacitance from 0.1pF to 10,000uF.
  • Resistance from 0.1Ohm to 2MOhm.
  • Inductance measurement also shows DC winding resistance.
  • Display of "Component type and values", "Complex Impedance", "Magnitude/Phase" and "Admittance".
  • Test frequency displayed for all measurements.
  • Typical accuracy of 1.5% for inductors and capacitors (see spec table for details).
  • Typical accuracy of 1% for resistors.
  • Test lead complete with gold plated 2mm plugs and sockets.
  • Supplied with removable gold plated hook probes.

Parameter

Min

Typ

Max

Note

Resistance

range

 

2MΩ

 

resolution

0.1Ω

0.2Ω

 

 

accuracy

Typically ±1.0% ±0.6Ω

1,2,6

Capacitance

range

0pF

 

10000µF

 

resolution

0.1pF

0.2pF

 

 

accuracy

 Typically ±1.5% ±0.6pF

1,2,5

Inductance

range

0µH

 

10H

 

resolution

0.1µH

0.2µH

 

 

accuracy

 Typically ±1.5% ±0.6µH

1,2,4

Passive Component Impedance

Re & Im

Typically ±1.5% ±10 LSD

4,5,6

Magnitude

Typically ±1.5% ±10 LSD

4,5,6

Phase

Typically ±5°

4,5,6

Measurement Sample Rate

0.5Hz

1.5Hz

2Hz

 

Peak test voltage (across O/C)

-1.05V

 

+1.05V

 

Peak test current (thru S/C)

-3.25mA

 

+3.25mA

 

Test frequency accuracy

1kHz

Typically ±0.5%

 

14.9254kHz

7

200kHz

 

Sine purity

Typically -60dB 3rd harmonic

 

Operating temperature range

10°C

 

40°C

3

Battery operating voltage

8.5V

 

13V

 

Notes for table above:
1. Within 12 months of factory calibration. Please contact us if you require a full re-calibration and/or certification of traceable calibration.
2. Specified at temperatures between 15°C and 30°C.
3. Subject to acceptable LCD visibility.
4. For inductances between 100µH and 100mH in fully auto mode.
5. For capacitances between 200pF and 500nF in fully auto mode.
6. For resistances between 10Ω and 1MΩ in fully auto mode.
7. For clarity, the 14.9254kHz test frequency is shown as 15kHz.

Dimensions per product (excluding leads) 103 x 70 x 20 mm (4.1" x 2.8" x 0.8")
Dimensions per product (packaged) 200 x 138 x 30 mm (7.9" x 5.4" x 1.2")
   
Weight per product (nett) 0.098kg (3.5oz)
Weight per product (packaged inc docs) 0.161kg (5.7oz)
   
Bulk order multiple 20, 80
   
Harmonisation / Commodity / Tariff Code 9030 3399 20 GB
   
Fundamental Materials Plastic, glass and metal.
   
Country of manufacture England (UK)
   
Certification CE, WEEE, ROHS

Όλες οι παραγγελίες αποστέλλονται εντός 1–2 εργάσιμων ημερών μετά την παραλαβή της πληρωμής.

  • Ελλάδα: Οι αποστολές πραγματοποιούνται μέσω ACS Courier.

  • Οι χρόνοι παράδοσης ενδέχεται να διαφέρουν ανάλογα με τον προορισμό και την υπηρεσία ταχυμεταφοράς. Οι πληροφορίες αποστολής (tracking) θα σας αποσταλούν μόλις η παραγγελία σας αποσταλεί.

  • Οι πληροφορίες που αφορούν τους δασμολογικούς κωδικούς και τη χώρα καταγωγής παρέχονται μόνο για λόγους αναφοράς και δεν αποτελούν νομικά δεσμευτικά στοιχεία. Συνιστάται ανεξάρτητη επαλήθευση όλων των ταξινομήσεων.